Calibration equipment

Calibration equipment

Calibration is an essential step in every precision measurement. It establishes the relationship between the sound pressure and the electrical output of the microphone.

Calibration can be performed at either 250 Hz or at 1 kHz. Both frequencies have their advantages and disadvantages.

250 Hz is in the frequency range where the frequency response of almost all microphones is flat and will therefore give the most accurate calibration.

If, however, the microphone is used in connection with measuring equipment with weighting filters, for example a sound level meter with A-weighting, the 250 Hz signal will be attenuated by the weighting network. In this case it might be advantageous to use a 1 kHz calibration frequency.

At 1 kHz, the weighting filters have 0 dB attenuation and will therefore not affect the calibration.

On the other hand, since the frequency response of the microphone is not flat, a small error could be introduced.

  1. AL0011 Calibration Stand for IEC 60318-1 Ear Simulator

    G.R.A.S. AL0011 Calibration Stand for IEC 60318-1 Ear Simulator

    Provides a convenient platform for calibrating IEC 60318-1 Ear Simulator e.g. G.R.A.S. RA0039.

    Learn More
  2. AL0010 Microphone Calibration Stand
    TBD

    G.R.A.S. AL0010 Microphone Calibration Stand

    The G.R.A.S. AL0010 Calibration Stand provides a convenient platform for testing condenser microphones.

    Learn More
  3. 90AA Audiometer Calibration System
    Freq range:
    ANSI: S.1.40, S.1.43, S.1.11, S.3.6
    IEC: 60318-1 & -2

    G.R.A.S. 90AA Audiometer Calibration System

    The G.R.A.S. 90AA Audiometer Calibration System is easy and fast to set up and control and can be upgraded as your calibration needs change. From quick measuring of frequencies and test signal levels to harmonic distortion and representation of the values in one table together with the third octave band spectrum.

    Learn More
  4. 90AB Basic Audiometer Calibration Sys
    Freq range:
    ANSI: S.1.40, S.1.43, S.1.11, S.3.6
    IEC: 60318-1 & -2

    G.R.A.S. 90AB Basic Audiometer Calibration System

    The G.R.A.S. Audiometer Calibration Systems are configured to meet the requirements of modern audiometer calibration. They are easy and fast to set up and control, and can be upgraded as your calibration needs change.

    Learn More
  5. 90CA Microphone Calibration System
    Freq range:
    ANSI: S.1.10
    IEC: 60318-1 & -2

    G.R.A.S. 90CA Microphone Calibration System

    The G.R.A.S. 90CA Microphone CalibrationSystem provides for automated and reliable level and frequency response calibration of measurement microphones. The implemented calibration methods conform with relevant standards as listed in the specifications.

    Learn More
  6. 90CA-S2 Microphone Calibration System, PXI

    G.R.A.S. 90CA-S2 Microphone Calibration System, PXI

    The G.R.A.S. 90CA Microphone Calibration System provides for automated and reliable frequency response calibration of measurement microphones. The implemented calibration methods conform with relevant standards as listed in the specifications.

    Learn More
  7. /
    Standard: IEC 61043
    Special feature: Calibration coupler with two matched calibration chambers for the 50AI-LP Rugged Intensity Probe.

    G.R.A.S. 51AC-S1 Sound Intensity Calibration Adapter for 50AI-LP

    The 51AC-S1 Sound Intensity Calibration Adapter is a calibration adapter for sensitivity and phase calibration of the G.R.A.S. 50AI-LP CCP Rugged Intensity Probe. Learn More
  8. 51AC Sound Intensity Calibration Kit
    Standard: IEC 61043
    Special feature: Calibration coupler with two matched calibration chambers for G.R.A.S. Rugged Intensity Probes.

    G.R.A.S. 51AC Sound Intensity Calibration Kit

    The 51AC Sound Intensity Calibration Kit is a ready to use kit for sensitivity and phase calibration of G.R.A.S. Rugged Intensity Probes (50AI-LP, 50GI-P, 50GI-RP). The kit consists of a calibration adapter with two calibration chambers, a G.R.A.S. 42AA Pistonphone, Class 1, and a G.R.A.S. ZC0002K Barometer.

    Learn More
  9. 42AC High Pressure Pistonphone
    Sound pressure level: 134 dB
    Frequency: 250 Hz
    ANSI: S1.40
    IEC: 60942

    G.R.A.S. 42AC Pistonphone, high pressure, Class 1

    The G.R.A.S. 42AC Pistonphone, high pressure is a precision sound source for calibrating microphones. It is battery operated and produces a constant sound pressure level of 134 dB re. 20µPa (equivalent to 100 Pa) at 250 Hz, or 125.4 dBA re. 20µPa. 

    Learn More
  10. 42AP Intelligent Pistonphone
    Sound pressure level: 114 dB
    Frequency: 250 or 251.2 Hz
    ANSI: S1.40
    IEC: 60942

    G.R.A.S. 42AP Intelligent Pistonphone, Class 0

    The G.R.A.S. 42AP Pistonphone is a battery-operated, precision sound source for accurate and reliable calibration of measurement microphones, sound level meters and other sound measuring equipment.

    Learn More
  11. 42AA Pistonphone
    Sound pressure level: 114 dB
    Frequency: 250 Hz
    IEC: 60942

    G.R.A.S. 42AA Pistonphone, Class 1

    The G.R.A.S. Pistonphone 42AA is a battery-operated, precision sound source for accurate and reliable calibration of measurement microphones, sound level meters, and other sound measuring equipment.

    Learn More
  12. 42AB-S1 Sound Calibrator
    Sound pressure level: 124 dB
    Frequency: 250 Hz
    ANSI: S1.40
    IEC: 60942

    G.R.A.S. 42AB-S1 Sound Calibrator for LMS SCADAS 3D Binaural Headset

    The G.R.A.S. 42AB-S1 Sound Calibrator is a pocket sized battery operated sound calibrator for calibration of LMS SCADAS 3D Binaural Headset. It complies with the requirements of IEC 60942 Class 1. Learn More
  13. 42AB Sound Calibrator
    Sound pressure level: 114 dB
    Frequency: 1 kHz
    ANSI: S1.40
    IEC: 60942

    G.R.A.S. 42AB Sound Calibrator, Class 1

    The G.R.A.S. 42AB  Sound Calibrator is a small battery-operated precision microphone calibrator. The calibrator can be used directly on 1" microphones. Adapters for calibrating  1/2" (factory mounted), 1/4" and 1/8" microphones are included.

    Learn More
  14. 42AE Low Frequency Calibrator
    Sound pressure level: 140 dB
    Freq range: < 0.1 to 250 Hz
    ANSI: S1.10
    IEC: 60318-1 & -2

    G.R.A.S. 42AE Low Frequency Calibrator

    The G.R.A.S. 42AE Low-Frequency Calibrator permits microphone calibration at frequencies down to 0.01 Hz for both front and rear-vented microphones. It produces a constant sound pressure level down to very low frequencies.

    Learn More
  15. 51AB Phase Calibrator IEC 61043
    Freq range: 50 Hz to 6.3 kHz
    ANSI: S1.10
    IEC: 60943

    G.R.A.S. 51AB Phase Calibrator according to IEC 61043

    The Sound-intensity Calibrator 51AB is a coupler for phase and level calibrations of sound-intensity microphone pairs. It can be used for residual intensity testing, sound-intensity level calibration and particle velocity calibration as specified in IEC standard 1043 Electroacoustics-Instruments for the measurements of sound intensity- Measurement with pairs of pressure sensing microphones.

    Learn More
  16. 14AA Actuator Amplifier
    Freq range: 1 Hz to 200 kHz
    IEC: 61094-6

    G.R.A.S. 14AA Electrostatic Actuator Amplifier

    The G.R.A.S. 14AA Electrostatic Actuator Amplifier is a high-gain, high-voltage amplifier. The 14AA together with the available G.R.A.S. electrostatic actuators RA0014 and RA0015 comply with IEC 61094 -6 “Measurement microphones - Part 6: Electrostatic actuators for determination of frequency responses.”

    Learn More
  17. RA0015 1'' Electrostatic Actuator

    G.R.A.S. RA0015 1'' Electrostatic Actuator

    The G.R.A.S. RA0015 is an electrostatic actuator for testing the frequency response of standard 1” microphones. The RA0015 can be connected directly to the G.R.A.S. 14AA Actuator Supply.

    Learn More
  18. OP0024 Kit for Frequency Calibration of Flush-mount Microphone Sets

    G.R.A.S. OP0024 Kit for Frequency Calibration of Flush-mount Microphone Sets

    The G.R.A.S. OP0024 kit contains a calibration holder, electrostatic actuator and actuator calibration adapters for 1/8" and 1/4" size of  G.R.A.S. Flush-mount Microphone Sets. For 1/2" size no adapter is used.

    Learn More
  19. OP0026 Kit for Frequency Calibration of 1/4" Surface Microphones

    G.R.A.S. OP0026 Kit for Frequency Calibration of 1/4" Surface Microphones

    The G.R.A.S. OP0026 kit contains an electrostatic actuator and an actuator calibration holder for G.R.A.S. precision 1/4" surface microphones.

    Learn More
  20. RA0014 1/2'' Electrostatic Actuator

    G.R.A.S. RA0014 1/2'' Electrostatic Actuator

    The G.R.A.S. RA0014 1/2'' Electrostatic Actuator is an electrostatic actuator for testing the frequency response of standard 1/2”, 1/4” and 1/8" microphones; adapters are included for testing 1/4” and 1/8"microphones. The G.R.A.S. RA0014 can be connected directly to the G.R.A.S. 14AA Actuator Supply .

    Learn More