G.R.A.S. 40GK 1/2" Prepolarized Intensity Microphone Kit

Freq response: IEC 60651 Type 0 IEC
Dyn range: 27 dB(A) to 163 dB
Sensitivity: 12.5 mV/Pa
  • 40GK 1/2

Introduction

The 40GK is an IEC 61094-compliant, WS2F ½" prepolarized sound-intensity microphone pair. Read about the externally polarized equivalent [40AK].

The microphones in the kitt are two 40GI microphones – two phase-matched free-field measurement microphones with extremely well-controlled phase characteristics for use in sound-intensity probes. This microphone pair has a free-field frequency response that complies with IEC 61043 1993 Class 1 and IEC 60651 Type 1 in the range from 20 Hz to 10 kHz.

The 40GK kit also includes solid spacers for 12 mm, 25 mm, 50 mm, and 100 mm intensity-probe configurations, as well as adapters for the 26CB ¼" CCP preamplifier set. The 40GK is included in the G.R.A.S. 50GI CCP Sound Intensity Probe.

40GK is individually factory-calibrated and delivered with a calibration chart, stating its specific open-circuit sensitivity and pressure frequency response.

Typical applications and use

The 40GI is designed for sound-intensity and sound-power measurements, as well as sound-source localization, which is why it is included in the 50GI probe in the 40GK kit. Each 40GI microphone pair is phase matched according to the phase specifications for a Class 1 Sound Intensity Probe in accordance with international IEC 61043, Electroacoustics - Instruments for the Measurement of Sound Intensity - Measurements with Pairs of Pressure Sensing Microphones, 1993.

The quality of a sound intensity probe microphone is its ability to measure the real part of a complex sound intensity in highly reactive sound fields as well as in sound fields exposed to high levels of background noise. This ability depends largely on the phase responses of the microphone pair. The individual phase matching of each 40GI ensures that any differences in phase responses are extremely small.

The 40GI is also used for ranking of sound sources. When mounted in the 50GI sound-intensity probe, the microphones can pinpoint the area generating the most noise, which may then require additional measurements, depending on the measurement procedures and processes used. The sound-intensity microphones reveal the weak and strong points when identifying noise sources. Sound-source ranking is useful as long as the background noise doesn't exceed the noise source.

Compatibility

The 40GK includes straight and right-angled adapters for ¼" CCP preamplifiers, which requires an input module that supports this technology with a BNC or Microdot connector.

In the 50GI Sound-Intensity Probe, the 40GK pair is combined with the 26CB ¼" CCP preamplifier set.

System verification

For daily verification and check of your measurement setup, we recommend using a calibrator like G.R.A.S. Sound Level Calibrator 42AB.

For proper sensitivity calibration, we recommend using a pistonphone like G.R.A.S. Intelligent Pistonphone 42AP.

Quality and warranty

All G.R.A.S. microphones are made of high-quality materials that will ensure life-long stability and robustness. The microphones are all assembled in verified clean-room environments by skilled and dedicated operators with many years of expertise in this field.

The microphone diaphragm, body, and improved protection grid are made of high-grade stainless steel, which makes the microphone resistant to physical damage, as well as corrosion caused by aggressive air or gasses.

This, combined with the enforced gold-plated microphone terminal which guarantees a highly reliable connection, enables G.R.A.S. to offer 5 years warranty against defective materials and workmanship.

Service

If you accidentally damage the diaphragm on a G.R.A.S. microphone, we can—in most cases—replace it at a very reasonable cost and with a short turn-around time. This not only protects your investment, but also pleases your quality assurance department because you don't have to worry about new serial numbers, etc.

Calibration

Before leaving the factory, all G.R.A.S. microphones are calibrated in a controlled laboratory environment using traceable calibration equipment.

Depending on the use, measurement environment, and internal quality control programs, we recommend recalibrating the microphone at least once a year.

Frequency range (±1 dB) Hz IEC 60651 Type 0 IEC
Dynamic range lower limit (microphone thermal noise) dB(A) 20
Dynamic range lower limit with G.R.A.S. preamplifier dB(A) 27
Dynamic range upper limit dB 163
Dynamic range upper limit with G.R.A.S. preamplifier @ +28 V / ±14 V power supply dB 153
Dynamic range upper limit with G.R.A.S. preamplifier @ +120 V / ±60 V power supply dB 163
Dynamic range upper limit with G.R.A.S. CCP preamplifier dB 150
Polarization voltage V 0 V / CCP
Microphone venting Rear
IEC 61094-4 Compliance WS2P
Temperature range, operation °C / °F -40 to 120 / -40 to 248
Temperature range, storage °C / °F -40 to 85 / -40 to 185
Temperature coefficient @250 Hz dB/°C / dB/°F -0.01 / -0.006
Static pressure coefficient @250 Hz dB/kPa -0.014
Humidity range non condensing % RH 0 to 100
Humidity coefficient @250 Hz dB/% RH -0.001
Influence of axial vibration @1 m/s² dB re 20 µPa 66
CE/RoHS compliant/WEEE registered Yes / Yes, Yes
Weight g / oz 7 / 0.247

½” Microphone matched pair

40GI

12 mm spacer

RA0266

25 mm spacer

RA0265

50 mm spacer

RA0264

100 mm spacer

RA0263

Straight adapter for ½” microphone to ¼” preamplifier

RA0003

Right-angled adapter for ½” microphone to ¼” preamplifier (2 pcs)

RA0001

Optional Accessories for 40GK:

Sound Intensity Calibrator

51AB